Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 23, 2020, 06:50 AM
  • 18 0447_18 0446 _04232020_002821.mp4

Date
04/22/2020
W/O
823681
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14298
Time
11:50 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7578
Sewer Name
18 FLORENCE AVENUE TRUNK
City
santa fe springs
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_823681_TV18092_APR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0447
Downstream MH
18 0446
Dir. of Survey
Downstream
Length Surveyed
328.9 ft.
Total Length
328.9 ft.
Structural Index
2
Structural Quick
2T00
Structural Rating
208
O&M Index
2
O&M Quick
2Y00
O&M Rating
256
Overall Index
2
Overall Quick
Overall Rating
464
Pipe schematic from manhole 18 0447 to 18 0446
MH: 18 0447MH: 18 0446downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 04470 ft. MGO - General Observation - HEAVY STEAM/SMELL OF OIL0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start2.1 ft. IS - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.3 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start16.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"52.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN77.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"102.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"133 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start153.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"178 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"202.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"227.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"252.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN277.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"302.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"317.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"326 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish326 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish326 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Finish328.9 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish328.9 ft. IS - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish328.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0446

Observation photos (2)

  • Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    16.3 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (28)

DistanceCodeObservation
128.3TFC
277.8TFC
202.4TFC
2.1IS
302.7TFC
317.9TFC
133MWLS
52.4TFOPEN
328.9DAE
153.3TFC
227.5TFC
252.5TFOPEN
102.8TFC
326MWLS
326SSS
0AMH18 0447
0MGOHEAVY STEAM/SMELL OF OIL
16.3DAE
328.9IS
0MWM
2SSS
77.8TFC
328.9AMH18 0446
178TFC
2DAGS
326DAGS
0MWL
16.3TFC

Properties (6)

additional_info
SC411137
custom_field_two
3
customer
LACSD
datetime
2020-04-22T23:50:08-07:00
documentation
PROPIPE
is_lateral_inspection
false