Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 23, 2020, 08:31 AM
  • 18 0445_18 0444 _04232020_014357.mp4

Date
04/23/2020
W/O
823681
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14296
Time
1:31 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7528
Sewer Name
18 FLORENCE AVENUE TRUNK
City
santa fe springs
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_823681_TV18092_APR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0445
Downstream MH
18 0444
Dir. of Survey
Downstream
Length Surveyed
301 ft.
Total Length
301 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2c00
O&M Rating
358
Overall Index
2
Overall Quick
Overall Rating
358
Pipe schematic from manhole 18 0445 to 18 0444
MH: 18 0445MH: 18 0444downstream0 ft. MGO - General Observation - HEAVY STEAM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 04452 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 04 o'clock, , within 8 inches of joint: YES, Start2.5 ft. MMC - Material Change, Vitrified clay pipe2.5 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start2.5 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start - SLUDGE11.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"42.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"67.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"92.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6"117.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"168.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"193.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN219.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"244.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"260.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN268.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"284.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"298 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 04 o'clock, , within 8 inches of joint: YES, Finish301 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish301 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish301 ft. AMH - Downstream Manhole, Survey Ends - 18 0444

Observation photos (1)

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2.5 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
2.5MMC
219.4TFC
284.3TFC
2.5DAE
0MGOHEAVY STEAM
117.6TFC
168.4TFC
142.9TFC
2DAGS
0MWM
0MWL
92.7TFA
2.5DSZSLUDGE
42.3TFC
268.2TFC
67.4TFC
301DSZ
11.7TFC
193.7TFOPEN
260.4TFOPEN
301DAE
298DAGS
0AMH18 0445
301AMH18 0444
244.3TFC

Properties (6)

additional_info
SC411137
custom_field_two
3
customer
LACSD
datetime
2020-04-23T01:31:16-07:00
documentation
PROPIPE
is_lateral_inspection
false