15 0445_15 0444 _04162020_021813.mp4
0 ft. - General Observation - COCKROACHES IN MANHOLE
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start
5.4 ft. - Hole, from 11 to 01 o'clock, within 8 inches of joint: YES
5.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
25.8 ft. - Water Mark, 25 %of cross sectional area
48.5 ft. - General Observation - MAG COATING THROUGHOUT
124.8 ft. - Material Change, Vitrified clay pipe
171.2 ft. - Material Change, Concrete pipe (non-reinfored)
174.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
275.8 ft. - General Observation - COCKROACHES IN MANHOLE
| Distance | Code | Observation |
|---|---|---|
| 262.1 | TFC | — |
| 275.8 | SAP | — |
| 124.8 | SAP | — |
| 2 | SSS | — |
| 171.2 | MMC | — |
| 0 | AMH | 15 0445 |
| 25.8 | MWM | — |
| 48.5 | MGO | MAG COATING THROUGHOUT |
| 81 | TFA | — |
| 157.2 | TFA | — |
| 130.8 | TFA | — |
| 5.4 | H | — |
| 48.5 | TFA | — |
| 0 | MWM | — |
| 277.8 | AMH | 15 0444 |
| 235.8 | TFA | — |
| 111.3 | TFC | — |
| 5.4 | FM | — |
| 0 | MGO | COCKROACHES IN MANHOLE |
| 275.8 | DAGS | — |
| 25.8 | MWL | — |
| 275.8 | MGO | COCKROACHES IN MANHOLE |
| 174.1 | SAP | — |
| 2 | SAP | — |
| 2 | DAGS | — |
| 124.8 | SSS | — |
| 124.8 | MMC | — |
| 0 | MWL | — |
| 184.1 | TFC | — |
| 211.2 | TFC | — |