Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 22, 2020, 08:57 AM
  • H 0378_H 0377_04222020_020036.mp4

Date
04/22/2020
W/O
823890
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00177
PipeID
P10807
Time
1:57 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7575
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_823890_TV18174_APR2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
66 in.
Width
66 in.
Upstream MH
H 0378
Downstream MH
H 0377
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole H 0378 to H 0377
MH: H 0378MH: H 0377downstream0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 0378 E0 ft. MWM - Water Mark, 100 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO2.1 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES2.1 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    2.1 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observations (6)

DistanceCodeObservation
0MWL
2.1SAP
0AMHH 0378 E
2.1MSAVIEW OF D/S SIPHON FROM U/S MH
2SSS
0MWM

Properties (6)

additional_info
SC411134
custom_field_two
2
customer
LACSD
datetime
2020-04-22T01:57:15-07:00
documentation
PROPIPE
is_lateral_inspection
false