Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 15, 2020, 08:06 AM
  • E 0209_01 0053A_04152020_012049.mp4

Date
04/15/2020
W/O
823817
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00209
PipeID
P02146
Time
1:06 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7568
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_823817_TV01254_APR2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0053A
Downstream MH
E 0209
Dir. of Survey
Upstream
Length Surveyed
156.7 ft.
Total Length
156.7 ft.
Structural Index
3
Structural Quick
413E
Structural Rating
154
O&M Index
2
O&M Quick
2E00
O&M Rating
62
Overall Index
2
Overall Quick
Overall Rating
216
Pipe schematic from manhole 01 0053A to E 0209
MH: 01 0053AMH: E 0209upstream0 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - E 02092.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish89.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"91.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"140.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"153.4 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES154.3 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start154.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start154.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start156.7 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE156.7 ft. MWL - Water Level, 5 %of cross sectional area156.7 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE156.7 ft. MWM - Water Mark, 10 %of cross sectional area156.7 ft. AMH - Downstream Manhole, Survey Begins - 01 0053A

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Other,  5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    3.3 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
67TFC
2CM
13.9TFC
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
2SSS
0MWL
156.7DSZ
16.5TFC
2.4DSZ
3.3FM
156.7CM
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWM
65.2TFC
0AMH01 0053A
156.7AMHE 0209
154SSS

Properties (6)

additional_info
SC411127
custom_field_two
3
customer
LACSD
datetime
2020-04-15T01:06:07-07:00
documentation
PROPIPE
is_lateral_inspection
false