Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2020, 11:30 AM
  • 04 0008_04 0007_5182020_050507.mp4

Date
05/18/2020
W/O
0823728
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00408
PipeID
P20046
Time
4:30 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1421
Sewer Name
04 DISTRICT #4 OUTFALL TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
03
Purpose
Routine Assessment
Project
20200514VMR_DISTRICT_4_OUTFALL_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
04 0007
Downstream MH
04 0008
Dir. of Survey
Upstream
Length Surveyed
314 ft.
Total Length
314 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 04 0007 to 04 0008
MH: 04 0007MH: 04 0008upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 04 o'clock, , within 8 inches of joint: YES, Finish0 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish0.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: YES, Finish306 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 04 o'clock, , within 8 inches of joint: YES, Start306 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: YES, Start306 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start314 ft. AMH - Upstream Manhole, Survey Begins - 05:03 AM314 ft. AMH - Upstream Manhole, Survey Ends - 05:43 AM314 ft. MWM - Water Mark, 45 %of cross sectional area314 ft. MWL - Water Level, 25 %of cross sectional area

Observations (10)

DistanceCodeObservation
8DAGS
314DAGS
313.9DAGS
8DAGS
314SSS
8SSS
0AMH05:03 AM
0AMH05:43 AM
0MWM
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2020-05-18T04:30:00-07:00
documentation
REVELES, CASTILLO, SKINNER
is_lateral_inspection