Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 17, 2020, 09:19 AM
  • 18 0037_18 0036 _04172020_023342.mp4

Date
04/17/2020
W/O
823834
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00689
PipeID
P13852
Time
2:19 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7572
Sewer Name
18 MILLS AVENUE TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_823834_TV18176_APR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0037
Downstream MH
18 0036
Dir. of Survey
Downstream
Length Surveyed
309.3 ft.
Total Length
309.3 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
183
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
183
Pipe schematic from manhole 18 0037 to 18 0036
MH: 18 0037MH: 18 0036downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 00370 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"51.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"57.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"106 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"112.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"159.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"163.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"213 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"217.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"279.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"309 ft. MGO - General Observation - SURFACE SPALLING THROUGHOUT THE REACH309.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish309.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK309.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0036309.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (20)

DistanceCodeObservation
217.2TF
279.3TFC
0AMH18 0037
213TFC
112.3TFC
39.7TF
309.3SAV
106TFC
309.3MGOCONNECTION AT MH 9 O'CLOCK
309.3AMH18 0036
273.4TFC
57.3TFC
163.9TFC
0MWM
51.1TFC
309MGOSURFACE SPALLING THROUGHOUT THE REACH
159.5TFC
309.3MGOCONNECTION AT MH 3 O'CLOCK
2.3SAV
0MWL

Properties (6)

additional_info
SC411131
custom_field_two
3
customer
LACSD
datetime
2020-04-17T02:19:42-07:00
documentation
PROPIPE
is_lateral_inspection
false