Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2020, 10:02 AM
  • 01 1179_01 1178_04132020_031749.mp4

Date
04/13/2020
W/O
823723
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00225
PipeID
P02033
Time
3:02 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7562
Sewer Name
01 WILCOX AVENUE TRUNK
City
BELL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_823723_TV01072_APR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1178
Downstream MH
01 1179
Dir. of Survey
Upstream
Length Surveyed
337.9 ft.
Total Length
337.9 ft.
Structural Index
3
Structural Quick
413L
Structural Rating
205
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
205
Pipe schematic from manhole 01 1178 to 01 1179
MH: 01 1178MH: 01 1179upstream0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 011795.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"7.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"9.7 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES51.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"54 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"56.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"107.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"110 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"160.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"163.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"214.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"217.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"273.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"276.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"317.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"319.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"335 ft. MGO - General Observation - MAG COAT335 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start337.9 ft. MWL - Water Level, 15 %of cross sectional area337.9 ft. MWM - Water Mark, 30 %of cross sectional area337.9 ft. AMH - Downstream Manhole, Survey Begins - 01 1178

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    286.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    328.2 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
177.2TF
227.9TF
174.3TF
0MWL
283.9TF
337.9SAP
230.5TFA
18.3TF
330.4TF
64.3TF
337.9AMH01179
2.9MGOMAG COAT
328.2FM
0MWM
61.8TF
123.5TF
2.9SAP
286.3TB
332.7TF
20.4TF
0AMH01 1178
120.6TF
281.3TF

Properties (6)

additional_info
SC411121
custom_field_two
3
customer
LACSD
datetime
2020-04-13T03:02:49-07:00
documentation
PROPIPE
is_lateral_inspection
false