Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2020, 10:31 AM
  • 01 1177_01 1176B_04132020_033712.mp4

Date
04/13/2020
W/O
823723
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00225
PipeID
P02031
Time
3:31 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7562
Sewer Name
01 WILCOX AVENUE TRUNK
City
BELL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_823723_TV01072_APR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1177
Downstream MH
01 1176B
Dir. of Survey
Downstream
Length Surveyed
66.8 ft.
Total Length
66.8 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
39
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
39
Pipe schematic from manhole 01 1177 to 01 1176B
MH: 01 1177MH: 01 1176Bdownstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 11770 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"30.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"66.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish66.8 ft. AMH - Downstream Manhole, Survey Ends - 01 1176B

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
66.8SAP
2.2SAP
0MWM
30.9TF
66.8AMH01 1176B
0MWL
0AMH01 1177
0MGOCONNECTION AT MH 3 O'CLOCK
16TF

Properties (6)

additional_info
SC411121
custom_field_two
3
customer
LACSD
datetime
2020-04-13T03:31:19-07:00
documentation
PROPIPE
is_lateral_inspection
false