- Date
- 04/13/2020
- W/O
- 823723
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00225
- PipeID
- P02001
- Time
- 11:27 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7563
- Sewer Name
- 01 WILCOX AVENUE TRUNK
- City
- SOUTH GATE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- RFIR_WO_823723_TV01072_APR2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 01 1151
- Downstream MH
- 01 1150
- Dir. of Survey
- Downstream
- Length Surveyed
- 181.2 ft.
- Total Length
- 181.2 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole 01 1151 to 01 1150