Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 8, 2020, 04:52 AM
  • D 0174_D 0173 _04072020_221226.mp4

Date
04/07/2020
W/O
818287
Weather
Light Rain
Operator/Surveyor
B.FUGATE
Sewer ID
Z00157
PipeID
P10050
Time
9:52 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7556
Sewer Name
D JOINT OUTFALL D - UNIT 6 RELIEF
City
LAWNDALE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_818287_TV05173_MAR2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
D 0174
Downstream MH
D 0173
Dir. of Survey
Downstream
Length Surveyed
689.6 ft.
Total Length
689.6 ft.
Structural Index
3
Structural Quick
5Z3Z
Structural Rating
1362
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
1362
Pipe schematic from manhole D 0174 to D 0173
MH: D 0174MH: D 0173downstream0 ft. AMH - Upstream Manhole, Survey Begins - D 01740 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.7 ft. MGO - General Observation - MAG COAT23.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start687 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish689.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish689.6 ft. AMH - Downstream Manhole, Survey Ends - D 0173689.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    23.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
23.3SSS
689.6SAP
689.6AMHD 0173
687SRV
6.7SAP
6.7MGOMAG COAT
0AMHD 0174
689.6SSS
0MWM
0MWL
2SRV

Properties (7)

additional_info
SC411115
custom_field_two
2
customer
LACSD
datetime
2020-04-07T21:52:07-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
29986