Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 3, 2020, 06:14 AM
  • 29 0338_29 0337 _04022020_234522.mp4

Date
04/02/2020
W/O
818332
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01017
PipeID
P24357
Time
11:14 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7373
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_818332_TV29105_MAR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0337
Downstream MH
29 0338
Dir. of Survey
Upstream
Length Surveyed
371.3 ft.
Total Length
371.3 ft.
Structural Index
3
Structural Quick
4234
Structural Rating
20
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
20
Pipe schematic from manhole 29 0337 to 29 0338
MH: 29 0337MH: 29 0338upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 03380.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 OCLOCK35.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6"41.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES89.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"164.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"171.3 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES175 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"192 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES208.2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"238.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"248.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"257.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES310.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES329.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"332.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"333.9 ft. FL - Fracture Multiple, from 07 to 08 o'clock, within 8 inches of joint: YES355.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"371.3 ft. AMH - Downstream Manhole, Survey Begins - 29 0337371.3 ft. MWL - Water Level, 10 %of cross sectional area371.3 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (6)

  • Fracture Multiple, from 07 to 08 o'clock, within 8 inches of joint: YES

    37.4 ft. - Fracture Multiple, from 07 to 08 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    60.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    113.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    179.3 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    200 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    329.5 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
122.9TF
196.3TF
41.4TB
16.1TF
179.3FL
336TF
163.1TBA
200FM
113.8FM
133TF
39.1TF
60.5FL
370.9MGOACTIVE CONNECTION AT MH 3 OCLOCK
371.3AMH29 0338
0AMH29 0337
0MWL
37.4FL
329.5FL
206.6TF
282.1TB
0MWM

Properties (6)

additional_info
SC400394
custom_field_two
3
customer
LACSD
datetime
2020-04-02T23:14:12-07:00
documentation
PRO PIPE
is_lateral_inspection
false