Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 3, 2020, 06:55 AM
  • 29 0337_29 0322 _04032020_001613.mp4

Date
04/02/2020
W/O
818332
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01017
PipeID
P24356
Time
11:55 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7373
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_818332_TV29105_MAR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0337
Downstream MH
29 0322
Dir. of Survey
Downstream
Length Surveyed
321.7 ft.
Total Length
321.7 ft.
Structural Index
3
Structural Quick
4334
Structural Rating
24
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
24
Pipe schematic from manhole 29 0337 to 29 0322
MH: 29 0337MH: 29 0322downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 03370 ft. MWL - Water Level, 5 %of cross sectional area25.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ACTIVE25.7 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: NO26.7 ft. FM - Fracture Multiple, from 04 to 08 o'clock, within 8 inches of joint: YES50.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"62.4 ft. FS - Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES81.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"144.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"169.3 ft. FL - Fracture Longitudinal, at 05 o'clock, within 8 inches of joint: YES172.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"197.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start203.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4" - ACTIVE246.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"256.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"282.4 ft. FM - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES283.3 ft. FM - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES319.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish321.7 ft. AMH - Downstream Manhole, Survey Ends - 29 0322

Observation photos (7)

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: NO

    25.7 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: NO

  • Fracture Multiple, from 04 to 08 o'clock, within 8 inches of joint: YES

    26.7 ft. - Fracture Multiple, from 04 to 08 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES

    62.4 ft. - Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 05 o'clock, within 8 inches of joint: YES

    169.3 ft. - Fracture Longitudinal, at 05 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    197.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    282.4 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    283.3 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
172.6TF
25.7CM
0MWM
197.2SAV
50.7TF
203.3TBACTIVE
0AMH29 0337
25.4TBACTIVE
282.4FM
321.7AMH29 0322
256.3TF
81.3TF
62.4FS
246.1TF
283.3FM
26.7FM
144.6TF
169.3FL
0MWL
319.6SAV

Properties (6)

additional_info
SC400394
custom_field_two
3
customer
LACSD
datetime
2020-04-02T23:55:12-07:00
documentation
PRO PIPE
is_lateral_inspection
false