Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 3, 2020, 07:35 AM
  • 29 0345_29 0322 _04032020_010740.mp4

Date
04/03/2020
W/O
818332
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01017
PipeID
P24340
Time
12:35 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7373
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_818332_TV29105_MAR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0345
Downstream MH
29 0322
Dir. of Survey
Downstream
Length Surveyed
478.3 ft.
Total Length
478.3 ft.
Structural Index
3
Structural Quick
3R00
Structural Rating
282
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
284
Pipe schematic from manhole 29 0345 to 29 0322
MH: 29 0345MH: 29 0322downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 03450 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 OCLOCK8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start141 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"255.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"357.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"477.8 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 05 to 07 o'clock - UNKNOWN UNDER FLOW478.3 ft. AMH - Downstream Manhole, Survey Ends - 29 0322478.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish478.3 ft. MGO - General Observation - "ZOOMED-IN" CAMERA TOWARD D/S MH

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MWM
0MWL
478.3AMH29 0322
478.3SAV
8SAV
255.1TF
357.3TF
477.8OBZUNKNOWN UNDER FLOW
0AMH29 0345
0MGOACTIVE CONNECTION AT MH 3 OCLOCK
141TF
478.3MGO"ZOOMED-IN" CAMERA TOWARD D/S MH

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2020-04-03T00:35:41-07:00
documentation
PRO PIPE
is_lateral_inspection
false