Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2020, 08:02 AM
  • 18 0919_18 0399 _04072020_011857.mp4

Date
04/07/2020
W/O
818454
Weather
Light Rain
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00699
PipeID
P14233
Time
1:02 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7514
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_818454_TV18173_MAR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0919
Downstream MH
18 0399
Dir. of Survey
Downstream
Length Surveyed
328.7 ft.
Total Length
328.7 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
325
O&M Index
2
O&M Quick
322L
O&M Rating
137
Overall Index
2
Overall Quick
Overall Rating
462
Pipe schematic from manhole 18 0919 to 18 0399
MH: 18 0919MH: 18 0399downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 10 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 18 09192 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - PEELING ANG FLAKING THROUGHOUT7.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"87.1 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: YES, 4", 6" - 25% GREASE/OPEN-LATERAL88 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: YES, 4", 6" - 35% GREASE/ROOTS/ACTIVE-LATERAL88 ft. RFC - Roots Fine Connection, at 02 o'clock, within 8 inches of joint: YES148.4 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"187.2 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"189.3 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"199.4 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"294.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"326.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish326.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish326.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish328.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE328.7 ft. AMH - Downstream Manhole, Survey Ends - 18 0399

Observation photos (5)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Connection, at 02 o'clock, within 8 inches of joint: YES

    88 ft. - Roots Fine Connection, at 02 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    328.7 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (22)

DistanceCodeObservation
189.3TBA
88TBD35% GREASE/ROOTS/ACTIVE-LATERAL
87.1TBD25% GREASE/OPEN-LATERAL
0MWL
199.4TBA
148.4TBA
326.7DAGS
187.2TBA
88RFC
0MWM
328.7MGOCOCKROACHES IN MANHOLE
328.7AMH18 0399
326.7SSS
326.7SAP
2SSS
7.2TBA
294.9TBA
2DAGS
2SAP
0MGOCONN @ MH 10 O'CLOCK/ACTIVE
2MGOPEELING ANG FLAKING THROUGHOUT
0AMH18 0919

Properties (6)

additional_info
SC411203
custom_field_two
3
customer
LACSD
datetime
2020-04-07T01:02:39-07:00
documentation
PRO PIPE
is_lateral_inspection
false