Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2020, 05:12 AM
  • 18 0379_18 0378 _03172020_222650.mp4

Date
03/17/2020
W/O
818430
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00690
PipeID
P14213
Time
10:12 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7443
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Routine Assessment
Project
RFIR_WO_818430_TV18095_MAR2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0379
Downstream MH
18 0378
Dir. of Survey
Downstream
Length Surveyed
351.4 ft.
Total Length
351.4 ft.
Structural Index
4
Structural Quick
4M00
Structural Rating
272
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
3
Overall Quick
Overall Rating
410
Pipe schematic from manhole 18 0379 to 18 0378
MH: 18 0379MH: 18 0378downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 03790 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - VERMIN - RAT @ 3 O'CLOCK - BELOW MH COVER0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES14.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start19.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"89.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"184 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6" - CRACKED CAP290.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6" - CRACKED CAP342.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6" - CRACKED CAP349.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE349.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish349.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish351.4 ft. AMH - Downstream Manhole, Survey Ends - 18 0378

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    6.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    14.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    349.4 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (18)

DistanceCodeObservation
349.4MGOCOCKROACHES IN MANHOLE
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
290.5TFCCRACKED CAP
0AMH18 0379
349.4DAGS
6.2FM
19.1TFC
0MGOCOCKROACHES IN MANHOLE
351.4AMH18 0378
0MGOVERMIN - RAT @ 3 O'CLOCK - BELOW MH COVER
0MWM
89.5TFC
2DAGS
184TFCCRACKED CAP
342.9TFCCRACKED CAP
0MWL
349.4FM
14.4FM

Properties (6)

additional_info
SC398833
custom_field_two
2
customer
LACSD
datetime
2020-03-17T22:12:38-07:00
documentation
PRO PIPE
is_lateral_inspection
false