Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 31, 2020, 10:18 AM
  • 01 0453_01 0452_03312020_033004.mp4

Date
03/31/2020
W/O
818867
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00208
PipeID
P00935
Time
3:18 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7497
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_818867_TV01032_MAR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0453
Downstream MH
01 0452
Dir. of Survey
Downstream
Length Surveyed
296.6 ft.
Total Length
296.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 01 0453 to 01 0452
MH: 01 0453MH: 01 0452downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 04530 ft. MWL - Water Level, 5 %of cross sectional area2.5 ft. MGO - General Observation - PIPE IS LINED8.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"13.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"39 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"46.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"57.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"77.3 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6" - POSSIBLE GREASE IN LATERAL87.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"107.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"110 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"122.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"125.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"160.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"212.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"232.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"240.3 ft. RML - Roots Medium Lateral, at 10 o'clock, 40 %, within 8 inches of joint: NO240.3 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - ROOTS IN LATERAL263.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"296.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK296.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0452

Observations (23)

DistanceCodeObservation
232.9TF
107.4TF
296.6MGOCONNECTION AT MH 3 O'CLOCK
125.2TF
77.3TFDPOSSIBLE GREASE IN LATERAL
2.5MGOPIPE IS LINED
46.7TF
13.3TF
212.2TF
0MWM
57.2TF
160.9TF
0AMH01 0453
39TF
240.3RML
8.2TF
0MWL
87.1TFA
296.6AMH01 0452
110TF
122.9TF
240.3TFDROOTS IN LATERAL
263.6TF

Properties (8)

additional_info
SC411104
custom_field_two
4
customer
LACSD
datetime
2020-03-31T03:18:41-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP
year_laid
37179