Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 31, 2020, 10:42 AM
  • 01 0451_01 0450_03312020_035426.mp4

Date
03/31/2020
W/O
818867
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00208
PipeID
P00933
Time
3:42 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7497
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_818867_TV01032_MAR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0451
Downstream MH
01 0450
Dir. of Survey
Downstream
Length Surveyed
283.9 ft.
Total Length
283.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 01 0451 to 01 0450
MH: 01 0451MH: 01 0450downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 04510 ft. MWM - Water Mark, 25 %of cross sectional area3.5 ft. MGO - General Observation - PIPE IS LINED8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"20.8 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6" - OBSTRUCTION IN LATERAL47.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"59.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"95 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"96.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"120 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"123.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"130.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"166.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"197 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"219.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"224.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"247.9 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6" - OBSTRUCTION IN LATERAL270.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"283.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK283.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0450283.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observations (25)

DistanceCodeObservation
166.6TF
245.4TF
47.5TF
283.9MGOCONNECTION AT MH 3 O'CLOCK
96.9TF
59.2TF
270.9TF
8TF
0MWL
224.9TF
273.2TF
3.5MGOPIPE IS LINED
197TF
283.9AMH01 0450
120TF
0AMH01 0451
130.8TF
20.8TFDOBSTRUCTION IN LATERAL
247.9TFDOBSTRUCTION IN LATERAL
0MWM
173.9TF
283.9MGOCONNECTION AT MH 9 O'CLOCK
123.6TF
219.6TF
95TF