Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 3, 2020, 10:00 AM
  • 01 0391_01 0390_04032020_031336.mp4

Date
04/03/2020
W/O
818867
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE.
Sewer ID
Z00208
PipeID
P00870
Time
3:00 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7319
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_818867_TV01032_MAR2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0391
Downstream MH
01 0390
Dir. of Survey
Downstream
Length Surveyed
299.2 ft.
Total Length
299.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K00
O&M Rating
124
Overall Index
2
Overall Quick
Overall Rating
124
Pipe schematic from manhole 01 0391 to 01 0390
MH: 01 0391MH: 01 0390downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK capped0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 03912 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start43 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"69 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6", 6" - DEBRIS94.8 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6" - DEBRIS117.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"143.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"168.7 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6" - DEBRIS194.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"221.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"269.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"294.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"295 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish299.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0390

Observations (17)

DistanceCodeObservation
221.3TF
0MWL
43TFA
294.9TF
299.2AMH01 0390
117.5TF
69TFDDEBRIS
269.1TF
0MGOCONNECTION AT MH 3 O'CLOCK capped
2DAGS
194.5TF
143.2TFA
0MWM
295DAGS
168.7TFDDEBRIS
0AMH01 0391
94.8TFDDEBRIS

Properties (8)

additional_info
SC366947
custom_field_two
4
customer
LACSD
datetime
2020-04-03T03:00:01-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP
year_laid
35628