20 0156_20 0155_03262020_222623.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
29.7 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES
31.1 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR
54.7 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR
107.5 ft. - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YESR
| Distance | Code | Observation |
|---|---|---|
| 29.7 | DAGS | — |
| 322.6 | TFC | — |
| 173.6 | TFC | — |
| 333.3 | SSS | — |
| 0 | AMH | 20 0156 |
| 124.9 | TFC | — |
| 0 | MWL | — |
| 54.7 | RFJ | — |
| 335.3 | AMH | 20 0155 |
| 249.7 | TFC | — |
| 201.6 | TFC | — |
| 48.6 | TFC | — |
| 148.9 | TFC | — |
| 2 | DAGS | — |
| 0 | MWM | — |
| 107.5 | RFJ | — |
| 101 | TFC | — |
| 226.8 | TFC | — |
| 31.1 | RFJ | — |
| 302 | TFC | — |
| 24.4 | TFC | — |
| 77 | TFC | — |
| 2 | SAP | — |
| 333.3 | DAGS | — |
| 333.3 | SAP | — |
| 29.7 | TBA | — |
| 274.4 | TFC | — |
| 2 | SSS | — |