Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2020, 05:53 AM
  • B 0790_B 0789 _03102020_231058.mp4

Date
03/10/2020
W/O
813373
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00112
PipeID
P09257
Time
10:53 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7484
Sewer Name
B JOINT OUTFALL B - UNIT 8J
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_813373_TV15062_FEB2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
B 0790
Downstream MH
B 0789
Dir. of Survey
Downstream
Length Surveyed
552.1 ft.
Total Length
552.1 ft.
Structural Index
3
Structural Quick
5U3U
Structural Rating
1100
O&M Index
2
O&M Quick
2U00
O&M Rating
220
Overall Index
3
Overall Quick
Overall Rating
1320
Pipe schematic from manhole B 0790 to B 0789
MH: B 0790MH: B 0789downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 07902 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.8 ft. MGO - General Observation - 75% MAG COAT550 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish550 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish550 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish552.1 ft. AMH - Downstream Manhole, Survey Ends - B 0789552.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - 75% MAG COAT

    4.8 ft. - General Observation - 75% MAG COAT

Observations (13)

DistanceCodeObservation
550SSS
2SRV
0MWM
2SSS
552.1AMHB 0789
4.8MGO75% MAG COAT
2.8SAV
0MWL
550SRV
2DAGS
0AMHB 0790
550DAGS
552.1SAV

Properties (6)

additional_info
SC398891
custom_field_two
3
customer
LACSD
datetime
2020-03-10T22:53:43-07:00
documentation
PROPIPE
is_lateral_inspection
false