Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2020, 07:00 AM
  • 17 0073_17 0072_4132020_002552.mp4

Date
04/13/2020
W/O
0824366
Weather
Light Rain
Operator/Surveyor
REVELES
Sewer ID
Z00668
PipeID
P13792
Time
12:00 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1392
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
ALTADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
03
Purpose
Maintenance Related
Project
20200413VMR_DISTRICT_17_MAIN_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
17 0073
Downstream MH
17 0072
Dir. of Survey
Downstream
Length Surveyed
338.2 ft.
Total Length
338.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 17 0073 to 17 0072
MH: 17 0073MH: 17 0072downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:02 AM263.6 ft. RFJ - Roots Fine Joint, from 07 to 10 o'clock, within 8 inches of joint: YESR338.2 ft. AMH - Downstream Manhole, Survey Ends - 12:15 AM

Observation photos (1)

  • Roots Fine Joint, from 07 to 10 o'clock, within 8 inches of joint: YESR

    263.6 ft. - Roots Fine Joint, from 07 to 10 o'clock, within 8 inches of joint: YESR

Observations (5)

DistanceCodeObservation
338.2AMH12:15 AM
0MWL
0MWM
263.6RFJ
0AMH12:02 AM

Properties (4)

customer
LACSD
datetime
2020-04-13T00:00:00-07:00
documentation
REVELES, OLIVER III, CASTILLO, SKINNER
is_lateral_inspection
false