Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2020, 09:23 AM
  • J 0330_J 0329 _03182020_024551.mp4

Date
03/18/2020
W/O
813453
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00059
PipeID
P11574
Time
2:23 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7444
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
PALOS VERDES ESTATES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_813453_TV05363_FEB2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
J 0330
Downstream MH
J 0329
Dir. of Survey
Downstream
Length Surveyed
317.1 ft.
Total Length
317.1 ft.
Structural Index
3
Structural Quick
3311
Structural Rating
10
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole J 0330 to J 0329
MH: J 0330MH: J 0329downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 03300 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start22.2 ft. CM - Crack Multiple, from 06 to 09 o'clock, within 8 inches of joint: YES26.3 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start35.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"106 ft. JOM - Joint Offset Medium141.9 ft. MMC - Material Change, Cast Iron145.7 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start183.2 ft. MMC - Material Change, Vitrified clay pipe183.2 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish302.5 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"315.9 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish315.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish317.1 ft. AMH - Downstream Manhole, Survey Ends - J 0329

Observation photos (7)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 06 to 09 o'clock, within 8 inches of joint: YES

    22.2 ft. - Crack Multiple, from 06 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    26.3 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • Joint Offset Medium

    106 ft. - Joint Offset Medium

  • Material Change, Cast Iron

    141.9 ft. - Material Change, Cast Iron

  • Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    145.7 ft. - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Material Change, Vitrified clay pipe

    183.2 ft. - Material Change, Vitrified clay pipe

Observations (16)

DistanceCodeObservation
302.5TBC
26.3CM
315.9CM
106JOM
183.2MMC
145.7SCP
22.2CM
141.9MMC
317.1AMHJ 0329
0AMHJ 0330
315.9DAGS
0MWM
183.2SCP
35.8TFC
0MWL
0DAGS

Properties (6)

additional_info
SC398834
custom_field_two
3
customer
LACSD
datetime
2020-03-18T02:23:30-07:00
documentation
PRO PIPE
is_lateral_inspection
false