Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 28, 2020, 07:53 AM
  • J 0321A_J 0321_02282020_011408.mp4

Date
02/27/2020
W/O
813508
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00059
PipeID
P11565
Time
11:53 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7469
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
RANCHO PALOS VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_813508_TV05330_FEB2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
J 0321A
Downstream MH
J 0321
Dir. of Survey
Downstream
Length Surveyed
283.1 ft.
Total Length
283.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1300
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole J 0321A to J 0321
MH: J 0321AMH: J 0321downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 10 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 8 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - J 0321A0 ft. MWM - Water Mark, 20 %of cross sectional area3.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.4 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES79.5 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES129.6 ft. RFJ - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES242.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"283.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish283.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK283.2 ft. AMH - Downstream Manhole, Survey Ends - J 0321

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
283.2CM
0MWL
79.5RFJ
242.6TF
283.2MGOCONNECTION AT MH 9 O'CLOCK
24.4RFJ
0MGOCONNECTION AT MH 10 O'CLOCK
129.6RFJ
3.5CM
0MGOCONNECTION AT MH 8 O'CLOCK
0AMHJ 0321A
0MWM
283.2AMHJ 0321

Properties (6)

additional_info
SC398875
custom_field_two
3
customer
LACSD
datetime
2020-02-27T23:53:25-08:00
documentation
PROPIPE
is_lateral_inspection
false