21 0906_21 0905 _02262020_010313.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
94.1 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES
125.2 ft. - Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES
128.3 ft. - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES
138.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
247.4 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES
345.2 ft. - Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 138.9 | TFC | — |
| 2 | DAGS | — |
| 294.8 | TFC | — |
| 138.2 | CL | — |
| 343.7 | TFC | — |
| 242.6 | TFC | — |
| 240 | TFC | — |
| 0 | MWL | — |
| 125.2 | CS | — |
| 141.8 | TFC | — |
| 94.1 | FM | — |
| 0 | MGO | CONNECTION AT MH 3 AND 9 OCLOCK (BOTH ACTIVE) |
| 247.4 | CM | — |
| 0 | MWM | — |
| 193.8 | TFA | — |
| 358.7 | DAGS | — |
| 292 | TFA | — |
| 128.3 | FM | — |
| 360.5 | AMH | 21 0905 |
| 341.2 | TFC | — |
| 345.2 | FM | — |
| 0 | AMH | 21 0906 |
| 191.3 | TFC | — |