Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 19, 2020, 07:57 AM
  • A 0516_A 0515 _02192020_013225.mp4

Date
02/18/2020
W/O
813372
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00315
PipeID
P07752
Time
11:57 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7459
Sewer Name
A JOA-1A DISTRICT 5 INTERCEPTOR
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_813372_TV05119_FEB2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
A 0516
Downstream MH
A 0515
Dir. of Survey
Downstream
Length Surveyed
652.3 ft.
Total Length
652.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole A 0516 to A 0515
MH: A 0516MH: A 0515downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 05160 ft. MWL - Water Level, 35 %of cross sectional area0.1 ft. MWM - Water Mark, 45 %of cross sectional area4.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start652.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish652.3 ft. AMH - Downstream Manhole, Survey Ends - A 0515

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0AMHA 0516
652.3SAP
652.3AMHA 0515
0.1MWM
0MWL
4.5SAP

Properties (7)

additional_info
SC398864
custom_field_three
AGGREGATE PROJECTING
custom_field_two
2
customer
LACSD
datetime
2020-02-18T23:57:12-08:00
documentation
PROPIPE
is_lateral_inspection
false