Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 25, 2020, 10:31 AM
  • 17 0015_17 0014 _02252020_035653.mp4

Date
02/25/2020
W/O
813472
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00668
PipeID
P21489
Time
2:31 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7418
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_813472_TV17010_FEB2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
17 0015
Downstream MH
17 0014
Dir. of Survey
Downstream
Length Surveyed
394.2 ft.
Total Length
394.2 ft.
Structural Index
3
Structural Quick
5132
Structural Rating
13
O&M Index
2
O&M Quick
4127
O&M Rating
18
Overall Index
3
Overall Quick
Overall Rating
31
Pipe schematic from manhole 17 0015 to 17 0014
MH: 17 0015MH: 17 0014downstream0 ft. AMH - Upstream Manhole, Survey Begins - 17 00150 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start44.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - HEAVY SPALLING WITH CHIPPING66.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES78.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start79 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - TAP & CAP CRACKED89.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6" - CRACKED CAP120.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"135.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"158.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"185.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6" - TAP & CAP CRACKED196.9 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - CAP CRACKED229.3 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS IN TAP - 75%236.9 ft. TBC - Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"265.4 ft. HVV - Hole Void Visible, from 01 to 04 o'clock, within 8 inches of joint: YES - WITH SOME SOIL277.1 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"293.2 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - CAP CRACKED309.2 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"314.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish321.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"333.2 ft. TBC - Tap Break-In Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"341.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"357.4 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"366 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"373.8 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"385.6 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"392.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish392.1 ft. MGO - General Observation - ROACHES IN MH392.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish394.2 ft. AMH - Downstream Manhole, Survey Ends - 17 0014

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - HEAVY SPALLING WITH CHIPPING

    44.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - HEAVY SPALLING WITH CHIPPING

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    66.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    78.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Hole Void Visible, from 01 to 04 o'clock, within 8 inches of joint: YES - WITH SOME SOIL

    265.4 ft. - Hole Void Visible, from 01 to 04 o'clock, within 8 inches of joint: YES - WITH SOME SOIL

  • General Observation - ROACHES IN MH

    392.1 ft. - General Observation - ROACHES IN MH

Observations (32)

DistanceCodeObservation
293.2TBCCAP CRACKED
392.1CM
2DAGS
392.1MGOROACHES IN MH
366TBC
341.5TBA
196.9TBCCAP CRACKED
185.7TFCTAP & CAP CRACKED
314.8SSS
321.2TB
236.9TBC
0AMH17 0015
357.4TBA
0MWL
265.4HVVWITH SOME SOIL
373.8TBA
392.1DAGS
229.3TBAROOTS IN TAP - 75%
333.2TBC
309.2TBC
44.2SSSHEAVY SPALLING WITH CHIPPING
158.6TF
0MWM
135.6TFA
277.1TBA
66.5CM
394.2AMH17 0014
79TFCTAP & CAP CRACKED
120.5TFA
78.3CM
89.9TFCCRACKED CAP
385.6TBA

Properties (7)

additional_info
SC398807
custom_field_three
MULTPL. CRCKS. / HOLE: VOID&SOIL/HVY.SPALL. CHIPNG
custom_field_two
1
customer
LACSD
datetime
2020-02-25T02:31:13-08:00
documentation
PRO PIPE
is_lateral_inspection
false