Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2020, 11:26 AM
  • J 0270_J 0269_02262020_043006.mp4

Date
02/26/2020
W/O
813409
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00059
PipeID
P11509
Time
3:26 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7466
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
RANCHO PALOS VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
45
Purpose
Routine Assessment
Project
RFIR_WO_813409_TV05169_FEB2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
J 0270
Downstream MH
J 0269
Dir. of Survey
Downstream
Length Surveyed
35.5 ft.
Total Length
35.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole J 0270 to J 0269
MH: J 0270MH: J 0269downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 02700 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area5.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.1 ft. MGO - General Observation - MAG COAT35.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK35.5 ft. AMH - Downstream Manhole, Survey Ends - J 026935.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
35.5MGOCONNECTION AT MH 9 O'CLOCK
35.5AMHJ 0269
0AMHJ 0270
5.1SAV
0MWL
35.5SAV
0MGOCONNECTION AT MH 9 O'CLOCK
5.1MGOMAG COAT
0MWM

Properties (6)

additional_info
SC398871
custom_field_two
3
customer
LACSD
datetime
2020-02-26T03:26:38-08:00
documentation
PROPIPE
is_lateral_inspection
false