Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 27, 2020, 08:07 AM
  • J 0267_J 0266_02272020_011800.mp4

Date
02/27/2020
W/O
813409
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00059
PipeID
P11506
Time
12:07 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7467
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
RANCHO PALOS VERDES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
46
Purpose
Routine Assessment
Project
RFIR_WO_813409_TV05169_FEB2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
J 0267
Downstream MH
J 0266
Dir. of Survey
Downstream
Length Surveyed
286 ft.
Total Length
286 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole J 0267 to J 0266
MH: J 0267MH: J 0266downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - j 02672.1 ft. MGO - General Observation - MAG COAT2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start286 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish286 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK286 ft. AMH - Downstream Manhole, Survey Ends - J 0266

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
286SAV
0MWM
286MGOCONNECTION AT MH 9 O'CLOCK
2.1MGOMAG COAT
286AMHJ 0266
0MWL
0AMHj 0267
2.1SAV

Properties (6)

additional_info
SC398872
custom_field_two
3
customer
LACSD
datetime
2020-02-27T00:07:15-08:00
documentation
PROPIPE
is_lateral_inspection
false