- Date
- 02/24/2020
- W/O
- 813409
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00059
- PipeID
- P11537
- Time
- 10:56 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7465
- Sewer Name
- J JOINT OUTFALL J - UNIT 1G
- City
- RANCHO PALOS VERDES
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 41
- Purpose
- Routine Assessment
- Project
- RFIR_WO_813409_TV05169_FEB2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- J 0296
- Downstream MH
- J 0295
- Dir. of Survey
- Downstream
- Length Surveyed
- 414.9 ft.
- Total Length
- 414.9 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 3
- O&M Quick
- 4221
- O&M Rating
- 10
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole J 0296 to J 0295 Observation photos (3)

4.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

362.5 ft. - Roots Medium Barrell, from 12 to 05 o'clock, 15 %, within 8 inches of joint: YES

362.5 ft. - Roots Ball Lateral, at 02 o'clock, 55 %