Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 25, 2020, 10:59 AM
  • J 0294_J 0293_02252020_041138.mp4

Date
02/25/2020
W/O
813409
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00059
PipeID
P11535
Time
2:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7465
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
RANCHO PALOS VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
45
Purpose
Routine Assessment
Project
RFIR_WO_813409_TV05169_FEB2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
J 0294
Downstream MH
J 0293
Dir. of Survey
Downstream
Length Surveyed
412.6 ft.
Total Length
412.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole J 0294 to J 0293
MH: J 0294MH: J 0293downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 02940 ft. MWM - Water Mark, 25 %of cross sectional area3.3 ft. MGO - General Observation - MAG COAT3.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start412.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish412.7 ft. AMH - Downstream Manhole, Survey Ends - J 0293412.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
3.3MGOMAG COAT
412.7SAV
0AMHJ 0294
0MWM
412.7AMHJ 0293
412.7MGOCONNECTION AT MH 3 O'CLOCK
3.3SAV

Properties (6)

additional_info
SC398870
custom_field_two
3
customer
LACSD
datetime
2020-02-25T02:59:17-08:00
documentation
PROPIPE
is_lateral_inspection
false