Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2020, 06:30 AM
  • J 0288_J 0287_02252020_234038.mp4

Date
02/25/2020
W/O
813409
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00059
PipeID
P11529
Time
10:30 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7466
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
RANCHO PALOS VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
45
Purpose
Routine Assessment
Project
RFIR_WO_813409_TV05169_FEB2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
J 0288
Downstream MH
J 0287
Dir. of Survey
Downstream
Length Surveyed
356.4 ft.
Total Length
356.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole J 0288 to J 0287
MH: J 0288MH: J 0287downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - J 02880 ft. MWL - Water Level, 15 %of cross sectional area2.6 ft. MGO - General Observation - MAG COAT2.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start115 ft. RFB - Roots Fine Barrell, from 09 to 01 o'clock356.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish356.4 ft. AMH - Downstream Manhole, Survey Ends - J 0287

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
356.3SAV
0MWM
2.6MGOMAG COAT
0MGOCONNECTION AT MH 9 O'CLOCK
0AMHJ 0288
0MWL
2.7SAV
115RFB
356.4AMHJ 0287

Properties (6)

additional_info
SC398871
custom_field_two
3
customer
LACSD
datetime
2020-02-25T22:30:12-08:00
documentation
PROPIPE
is_lateral_inspection
false