- Date
- 03/20/2020
- W/O
- 0823979
- Weather
- Dry
- Operator/Surveyor
- REVELES
- Sewer ID
- Z00668
- PipeID
- P13750
- Time
- 1:44 AM
- Certificate
- U-115-06022630
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1380
- Sewer Name
- 17 DISTRICT #17 MAIN TRUNK
- City
- Altadena
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 17
- Page No.
- 03
- Purpose
- Maintenance Related
- Project
- 20200319VMR_DISTRICT_17_MAIN_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 17 0026
- Downstream MH
- 17 0027
- Dir. of Survey
- Upstream
- Length Surveyed
- 218.4 ft.
- Total Length
- 218.4 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 1
- O&M Quick
- 1100
- O&M Rating
- 1
- Overall Index
- 1
- Overall Quick
- —
- Overall Rating
- 1
Pipe schematic from manhole 17 0026 to 17 0027