Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 20, 2020, 08:44 AM
  • 17 0027_17 0026_3202020_014612.mp4

Date
03/20/2020
W/O
0823979
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00668
PipeID
P13750
Time
1:44 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1380
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
Altadena
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
03
Purpose
Maintenance Related
Project
20200319VMR_DISTRICT_17_MAIN_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
17 0026
Downstream MH
17 0027
Dir. of Survey
Upstream
Length Surveyed
218.4 ft.
Total Length
218.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 17 0026 to 17 0027
MH: 17 0026MH: 17 0027upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02:02 AM25.5 ft. RFC - Roots Fine Connection, from 02 to 04 o'clock, within 8 inches of joint: YES218.4 ft. MWM - Water Mark, 40 %of cross sectional area218.4 ft. MWL - Water Level, 20 %of cross sectional area218.4 ft. AMH - Downstream Manhole, Survey Begins - 01:44 AM

Observations (5)

DistanceCodeObservation
192.9RFC
0MWM
0MWL
0AMH01:44 AM
218.4AMH02:02 AM

Properties (4)

customer
LACSD
datetime
2020-03-20T01:44:00-07:00
documentation
REVELES, CASTILLO
is_lateral_inspection
false