Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2020, 08:26 AM
  • B 0475_B 0474_3182020_031710.mp4

Date
03/18/2020
W/O
0818972
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00094
PipeID
P08999
Time
1:26 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1379
Sewer Name
B JOINT OUTFALL B - UNIT 5D
City
Altadena
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
06
Purpose
Maintenance Related
Project
20200318VMR_JOINT_OUTFALL_B_UNIT_5D
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
B 0475
Downstream MH
B 0474
Dir. of Survey
Downstream
Length Surveyed
47.9 ft.
Total Length
47.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole B 0475 to B 0474
MH: B 0475MH: B 0474downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02:15 AM0 ft. MWM - Water Mark, 30 %of cross sectional area40.3 ft. RFL - Roots Fine Lateral, at 02 o'clock47.9 ft. AMH - Upstream Manhole, Survey Ends - 02:21 AM

Observation photos (1)

  • Roots Fine Lateral, at 02 o'clock

    40.3 ft. - Roots Fine Lateral, at 02 o'clock

Observations (5)

DistanceCodeObservation
0MWL
0AMH02:15 AM
0MWM
40.3RFL
47.9AMH02:21 AM

Properties (4)

customer
LACSD
datetime
2020-03-18T01:26:07-07:00
documentation
REVELES,OLIVER III, CASTILLO
is_lateral_inspection
false