Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 3, 2020, 06:13 AM
  • 15 0767_15 0766 _03022020_234053.mp4

Date
03/02/2020
W/O
813447
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00593
PipeID
P12968
Time
10:13 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7363
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_813447_TV15146_FEB2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0767
Downstream MH
15 0766
Dir. of Survey
Downstream
Length Surveyed
404.4 ft.
Total Length
404.4 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 15 0767 to 15 0766
MH: 15 0767MH: 15 0766downstream0 ft. MGO - General Observation - CONNECTIONS AT BOTH 3 AND 9 O'CLOCK AT MH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07670 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start22 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start113.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"114.2 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 8"116.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"117.7 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: YES, 8"168.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"171.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"272.1 ft. MGO - General Observation - MAG COATING ATTATCHED287.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"290.7 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"327.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 8"329.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"401.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish401.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish404.4 ft. MGO - General Observation - CONNECTIONS AT BOTH 3 AND 9 O'CLOCK AT MH404.4 ft. AMH - Downstream Manhole, Survey Ends - 15 0766

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    22 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COATING ATTATCHED

    272.1 ft. - General Observation - MAG COATING ATTATCHED

Observations (21)

DistanceCodeObservation
116.6TFC
2SAV
404.4MGOCONNECTIONS AT BOTH 3 AND 9 O'CLOCK AT MH
272.1MGOMAG COATING ATTATCHED
22SSS
327.3TB
113.4TFC
0MGOCONNECTIONS AT BOTH 3 AND 9 O'CLOCK AT MH
329.7TF
114.2TB
290.7TBC
0MWL
401.3SSS
401.3SAV
117.7TB
287.8TF
0AMH15 0767
0MWM
171.2TF
168.3TF
404.4AMH15 0766

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2020-03-02T22:13:55-08:00
documentation
PRO PIPE
is_lateral_inspection
false