Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2020, 08:54 AM
  • 05 0726_05 0725_03022020_022124.mp4

Date
03/02/2020
W/O
813507
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00521
PipeID
P05949
Time
12:54 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7472
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #1
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_813507_TV05333_FEB2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0726
Downstream MH
05 0725
Dir. of Survey
Downstream
Length Surveyed
377.5 ft.
Total Length
377.5 ft.
Structural Index
4
Structural Quick
4N00
Structural Rating
304
O&M Index
2
O&M Quick
3421
O&M Rating
17
Overall Index
4
Overall Quick
Overall Rating
321
Pipe schematic from manhole 05 0726 to 05 0725
MH: 05 0726MH: 05 0725downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 5 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 05 07260 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area3.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start48 ft. RFJ - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YES57.5 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES93.9 ft. RFJ - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES98.3 ft. RML - Roots Medium Lateral, at 02 o'clock, 30 %, within 8 inches of joint: NO98.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"161.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"224 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"234 ft. B - Broken, from 04 to 05 o'clock, within 8 inches of joint: YES284 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"331.6 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start331.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES337.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"338.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"347.3 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish377.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish377.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK377.5 ft. AMH - Downstream Manhole, Survey Ends - 05 0725

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

    57.5 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
0MWL
98.3RML
234B
3.1FM
161.3TF
377.5FM
331.6DSZ
0MGOCONNECTION AT MH 5 O'CLOCK
98.3TF
93.9RFJ
0AMH05 0726
338.7TF
377.5MGOCONNECTION AT MH 9 O'CLOCK
57.5RFJ
377.5AMH05 0725
331.6DAGS
0MGOCONNECTION AT MH 3 O'CLOCK
0MWM
224TF
347.3DSZ
284TF
337.7TFC
48RFJ

Properties (6)

additional_info
SC398878
custom_field_two
2
customer
LACSD
datetime
2020-03-02T00:54:43-08:00
documentation
PROPIPE
is_lateral_inspection
false