Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2020, 09:24 AM
  • 05 0725_05 0724_03022020_024453.mp4

Date
03/02/2020
W/O
813507
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00521
PipeID
P05948
Time
1:24 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7472
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #1
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_813507_TV05333_FEB2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 0725
Downstream MH
05 0724
Dir. of Survey
Downstream
Length Surveyed
355.2 ft.
Total Length
355.2 ft.
Structural Index
4
Structural Quick
4K3B
Structural Rating
273
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
277
Pipe schematic from manhole 05 0725 to 05 0724
MH: 05 0725MH: 05 0724downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 07250 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK5.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"26.6 ft. FM - Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES60.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"66.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish68.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start107.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"168.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"196.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"207.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"284.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"286 ft. MWM - Water Mark, 60 %of cross sectional area - High water mark changes355 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - Throughout the reach355.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK355.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish355.2 ft. AMH - Downstream Manhole, Survey Ends - 05 0724

Observation photos (6)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    26.6 ft. - Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    60.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    68.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    107.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    196.1 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (22)

DistanceCodeObservation
0MWL
5.6CM
355.2MGOCONNECTION AT MH 9 O'CLOCK
196.1TB
0MWM
355.2FM
355.2AMH05 0724
13.1TF
355SSSThroughout the reach
60.4TB
0AMH05 0725
68.2CM
286MWMHigh water mark changes
168.3TFC
66.9TFC
207.5TFC
107.3TB
0MGOCONNECTION AT MH 9 O'CLOCK
68.2FM
284.7TF
26.6FM
114.8TFC

Properties (6)

additional_info
SC398878
custom_field_two
2
customer
LACSD
datetime
2020-03-02T01:24:45-08:00
documentation
PROPIPE
is_lateral_inspection
false