Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 16, 2020, 10:01 AM
  • 18 0383_18 0382_3162020_030516.mp4

Date
03/16/2020
W/O
0823075
Weather
Heavy Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00690
PipeID
P14217
Time
3:01 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1378
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20200313MDM_NORTH_NORWALK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
18 0383
Downstream MH
18 0382
Dir. of Survey
Downstream
Length Surveyed
254.2 ft.
Total Length
254.2 ft.
Structural Index
2
Structural Quick
4139
Structural Rating
83
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
83
Pipe schematic from manhole 18 0383 to 18 0382
MH: 18 0383MH: 18 0382downstream0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:05AM11.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H11.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE17.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H29.7 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL33.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL67 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H70.2 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL79.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL79.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SL91.9 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT94.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H98.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL104.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H104.1 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL110.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL114 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL138.6 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL141.6 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - H157.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H172.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H175.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL178.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H181.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL185.4 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL188.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL191.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL200.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H209.8 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL225.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL231.9 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL237.7 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL237.7 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL240.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL243.8 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H247.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL250.1 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - SL254.2 ft. AMH - Downstream Manhole, Survey Ends - 3:40AM254.2 ft. MGO - General Observation - MH CONN 3:00 ACTIVE

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    240.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

Observations (42)

DistanceCodeObservation
33.2FLSL
29.7FCSL
172.8FLH
157.3FLH
104.1FCH
138.6FCSL
98.3FCSL
110.8FCSL
254.2AMH3:40AM
231.9FCSL
209.8FCSL
104.1FCSL
0MGOMH CONN 3:00 ACTIVE
141.6FCH
247.3FCSL
94.8FLH
79.5FCSL
11.1FCH
191.3FCSL
175.4FCSL
0MWL
188.2FCSL
11.1FLHAIRLINE
200.4FLH
114FCSL
67FCH
79.5FLSL
17.4FCH
178.3FCH
0MWM
243.8FLH
91.9FCSLIGHT
181.9FCSL
237.7FCSL
0AMH3:05AM
237.7FCSL
70.2FCSL
185.4FCSL
225.4FLSL
250.1FCSL
254.2MGOMH CONN 3:00 ACTIVE
240.8FMSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2020-03-16T03:01:00-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false