Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 16, 2020, 08:49 AM
  • 18 0384_18 0383_3162020_020444.mp4

Date
03/16/2020
W/O
0823075
Weather
Heavy Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00690
PipeID
P14218
Time
1:49 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1378
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20200313MDM_NORTH_NORWALK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
18 0384
Downstream MH
18 0383
Dir. of Survey
Downstream
Length Surveyed
254.9 ft.
Total Length
254.9 ft.
Structural Index
3
Structural Quick
3A29
Structural Rating
51
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
51
Pipe schematic from manhole 18 0384 to 18 0383
MH: 18 0384MH: 18 0383downstream0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:50AM0 ft. MWL - Water Level, 10 %of cross sectional area11.1 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT14.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE20.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL23.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H30 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H39.4 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H42.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL45.8 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL48.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H48.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL48.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL51.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H54.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H58 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL64.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SL73.5 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H79.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS79.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS79.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS79.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS254.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 40% SLIGHT254.5 ft. MGO - General Observation - MH CONN 3:00 ACTIVE254.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 40% HAIRLINE254.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 20% SLIGHT254.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 15% HAIRLINE254.9 ft. AMH - Downstream Manhole, Survey Ends - 2:20AM

Observations (30)

DistanceCodeObservation
23.5FLH
45.8FCSL
0MGOMH CONN 3:00 ACTIVE
48.5FLH
54.7FLH
39.4FLH
0MWM
73.5FCH
0AMH1:50AM
58FLSL
254.5FC40% SLIGHT
30FLH
254.9AMH2:20AM
254.5MGOMH CONN 3:00 ACTIVE
14.4FLHAIRLINE
48.5FCSL
20.7FCSL
79.5FCSLIGHT AT JOINTS
11.1FCSLIGHT
254.5FC40% HAIRLINE
79.5FCHAIRLINE AT JOINTS
79.5FLHAIRLINE AT JOINTS
64.1FLSL
0MWL
254.5FL20% SLIGHT
79.5FLSLIGHT AT JOINTS
42.2FCSL
48.5FCSL
254.5FL15% HAIRLINE
51.7FLH

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2020-03-16T01:49:49-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false