Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 12, 2020, 07:27 AM
  • 01 0359_01 0358_02112020_234056.mp4

Date
02/11/2020
W/O
808205
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00215
PipeID
P00833
Time
11:27 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7355
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
FLORENCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_808205_TV01077_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0358
Downstream MH
01 0359
Dir. of Survey
Upstream
Length Surveyed
320.5 ft.
Total Length
320.5 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
11
Pipe schematic from manhole 01 0358 to 01 0359
MH: 01 0358MH: 01 0359upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 035999 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES303.7 ft. CM - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES320.5 ft. AMH - Downstream Manhole, Survey Begins - 01 0358320.5 ft. MWM - Water Mark, 50 %of cross sectional area320.5 ft. MWL - Water Level, 30 %of cross sectional area

Observation photos (2)

  • Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

    16.8 ft. - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    221.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
0AMH01 0358
16.8CM
221.5FM
0MWM
320.5AMH01 0359
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2020-02-11T23:27:15-08:00
documentation
PRO PIPE
is_lateral_inspection
false