Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2020, 07:51 AM
  • 32 1045_32 1044D _02062020_000002.mp4

Date
02/05/2020
W/O
808159
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P25582
Time
11:51 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7401
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_808159_TV32025_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 1045
Downstream MH
32 1044D
Dir. of Survey
Downstream
Length Surveyed
87.3 ft.
Total Length
87.3 ft.
Structural Index
2
Structural Quick
4133
Structural Rating
45
O&M Index
2
O&M Quick
2B00
O&M Rating
34
Overall Index
2
Overall Quick
Overall Rating
79
Pipe schematic from manhole 32 1045 to 32 1044D
MH: 32 1045MH: 32 1044Ddownstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 10450.1 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED0.1 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start56.2 ft. MGO - General Observation - RUN LIST AND DATABASE STATE NRCP.68.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start74.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES74.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish84 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish84.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES85.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish87.3 ft. AMH - Downstream Manhole, Survey Ends - 32 1044D

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    68.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    74.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    84.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
56.2MGORUN LIST AND DATABASE STATE NRCP.
0.1MGOCONN @ MH 9 O'CLOCK/CAPPED
74.4FM
2SSS
74.4CM
85.9DAGS
0.1MGOCONN @ MH 3 O'CLOCK/CAPPED
0MWL
87.3AMH32 1044D
84.1CM
0MWM
68.6CM
84SSS
0AMH32 1045
2DAGS

Properties (6)

additional_info
SC398790
custom_field_two
3
customer
LACSD
datetime
2020-02-05T23:51:50-08:00
documentation
PRO PIPE
is_lateral_inspection
false