Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2020, 08:21 AM
  • 32 1047_32 1046 _02062020_003714.mp4

Date
02/06/2020
W/O
808159
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19494
Time
12:21 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7401
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_808159_TV32025_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 1047
Downstream MH
32 1046
Dir. of Survey
Downstream
Length Surveyed
522 ft.
Total Length
522 ft.
Structural Index
3
Structural Quick
413T
Structural Rating
521
O&M Index
2
O&M Quick
2T00
O&M Rating
208
Overall Index
2
Overall Quick
Overall Rating
729
Pipe schematic from manhole 32 1047 to 32 1046
MH: 32 1047MH: 32 1046downstream0 ft. MMC - Material Change, Vitrified clay pipe - PIPE MATERIAL NOT NRCP, VCP IS THE MATERIAL0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 10470 ft. MWL - Water Level, 25 %of cross sectional area0.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE0.1 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start225 ft. MGO - General Observation - ABANDONED MH226.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ABANDONED MH/CAPPED403 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES420.7 ft. MGO - General Observation - RUN LIST AND DATABASE STATE NRCP.520 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish520 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish520 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish522 ft. AMH - Downstream Manhole, Survey Ends - 32 1046

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0.1 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ABANDONED MH

    225 ft. - General Observation - ABANDONED MH

  • General Observation - CONN @ MH 3 O'CLOCK/ABANDONED MH/CAPPED

    226.5 ft. - General Observation - CONN @ MH 3 O'CLOCK/ABANDONED MH/CAPPED

Observations (17)

DistanceCodeObservation
0MMCPIPE MATERIAL NOT NRCP, VCP IS THE MATERIAL
2DAGS
0MWM
0.1MGOCOCKROACHES IN MANHOLE
2SSS
225MGOABANDONED MH
522AMH32 1046
520CM
0.1MGOCONN @ MH 9 O'CLOCK
520DAGS
0AMH32 1047
520SSS
7.2CM
403FM
0MWL
226.5MGOCONN @ MH 3 O'CLOCK/ABANDONED MH/CAPPED
420.7MGORUN LIST AND DATABASE STATE NRCP.

Properties (6)

additional_info
SC398790
custom_field_two
3
customer
LACSD
datetime
2020-02-06T00:21:25-08:00
documentation
PRO PIPE
is_lateral_inspection
false