Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2020, 06:04 AM
  • 08 0038_08 0037 _02052020_222214.mp4

Date
02/05/2020
W/O
808144
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00016
PipeID
P00040
Time
10:04 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7308
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_808144_TV08115_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0038
Downstream MH
08 0037
Dir. of Survey
Downstream
Length Surveyed
169.7 ft.
Total Length
169.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 08 0038 to 08 0037
MH: 08 0038MH: 08 0037downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 08 00382 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"55.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"108.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"150.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES157.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"159.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO166.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish169.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0037

Observation photos (2)

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    150.5 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

    159.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

Observations (13)

DistanceCodeObservation
166.5DAGS
108.6TFC
169.7AMH08 0037
150.5FL
0MWL
0MWM
157.2TFC
0MGOCONNECTION AT MH 3 O'CLOCK
6.6TFC
2DAGS
0AMH08 0038
159.4CL
55.6TFC

Properties (6)

additional_info
SC378789
custom_field_two
3
customer
LACSD
datetime
2020-02-05T22:04:00-08:00
documentation
PRO PIPE
is_lateral_inspection
false