Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2020, 06:24 AM
  • 08 0036_08 0035 _02052020_225541.mp4

Date
02/05/2020
W/O
808144
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00016
PipeID
P00038
Time
10:24 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
k7308
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_808144_TV08115_JAN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0036
Downstream MH
08 0035
Dir. of Survey
Downstream
Length Surveyed
329 ft.
Total Length
329 ft.
Structural Index
4
Structural Quick
5141
Structural Rating
18
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
148
Pipe schematic from manhole 08 0036 to 08 0035
MH: 08 0036MH: 08 0035downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 00362 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start33.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"84.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"134.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"188.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"190.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start198 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES198.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES207.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish236.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"279.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"325.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish329 ft. AMH - Downstream Manhole, Survey Ends - 08 0035

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    198.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
329AMH08 0035
188.3TFC
190.3FL
325.8DAGS
236.5TFC
84.7TFC
279.2TFC
0MWM
2DAGS
33.3TFC
0MWL
207.4FL
198.2FM
0AMH08 0036
198B
134.3TFC

Properties (6)

additional_info
SC378789
custom_field_two
2
customer
LACSD
datetime
2020-02-05T22:24:34-08:00
documentation
PRO PIPE
is_lateral_inspection
false