Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 7, 2020, 07:43 AM
  • 08 0011_08 0010_02072020_001052.mp4

Date
02/06/2020
W/O
808144
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00016
PipeID
P00011
Time
11:43 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
k7310
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_808144_TV08115_JAN2020
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
08 0011
Downstream MH
08 0010
Dir. of Survey
Downstream
Length Surveyed
268.5 ft.
Total Length
268.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 08 0011 to 08 0010
MH: 08 0011MH: 08 0010downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 00110 ft. MWL - Water Level, 30 %of cross sectional area2 ft. MGO - General Observation - MAG COAT THROUGHOUT8.4 ft. OBZ - Obstacles Other, 15 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS UNDER WATER263.5 ft. MGO - General Observation - MAG COAT THROUGHOUT END263.5 ft. OBZ - Obstacles Other, 15 %of cross sectional area, from 04 to 08 o'clock, Finish - DEBRIS UNDER WATER268.5 ft. AMH - Downstream Manhole, Survey Ends - 08 0010

Observation photos (1)

  • Obstacles Other, 15 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS UNDER WATER

    8.4 ft. - Obstacles Other, 15 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS UNDER WATER

Observations (8)

DistanceCodeObservation
268.5AMH08 0010
0MWM
0AMH08 0011
263.5MGOMAG COAT THROUGHOUT END
2MGOMAG COAT THROUGHOUT
263.5OBZDEBRIS UNDER WATER
8.4OBZDEBRIS UNDER WATER
0MWL

Properties (6)

additional_info
SC378791
custom_field_two
3
customer
LACSD
datetime
2020-02-06T23:43:25-08:00
documentation
PRO PIPE
is_lateral_inspection
false