Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 21, 2020, 08:51 AM
  • A 0610_A 0609 _01212020_005609.mp4

Date
01/21/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07815
Time
12:51 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7244
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
38
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Width
51 in.
Upstream MH
A 0610
Downstream MH
A 0609
Dir. of Survey
Downstream
Length Surveyed
189.6 ft.
Total Length
189.6 ft.
Structural Index
3
Structural Quick
3F2F
Structural Rating
185
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
185
Pipe schematic from manhole A 0610 to A 0609
MH: A 0610MH: A 0609downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 06100 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start5.1 ft. MGO - General Observation - MAG COAT5.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start187 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish189.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish189.6 ft. AMH - Downstream Manhole, Survey Ends - A 0609

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
189.6SAV
187SSS
0AMHA 0610
189.6AMHA 0609
5.3SAV
0MWL
0MWM
3SSS
5.1MGOMAG COAT

Properties (6)

additional_info
SC398539
custom_field_two
3
customer
LACSD
datetime
2020-01-21T00:51:08-08:00
documentation
PRO PIPE
is_lateral_inspection
false