Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2020, 06:17 AM
  • A 0594_A 0593 _01272020_224637.mp4

Date
01/27/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07799
Time
10:17 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7246
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
A 0594
Downstream MH
A 0593
Dir. of Survey
Downstream
Length Surveyed
923.3 ft.
Total Length
923.3 ft.
Structural Index
3
Structural Quick
3d2d
Structural Rating
918
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
918
Pipe schematic from manhole A 0594 to A 0593
MH: A 0594MH: A 0593downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 05943 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start3.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start457.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"764.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"920 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish923.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish923.3 ft. AMH - Downstream Manhole, Survey Ends - A 0593

Observations (10)

DistanceCodeObservation
457.5TF
0MWL
3SSS
0MWM
920SSS
3.1SAP
923.3AMHA 0593
0AMHA 0594
923.2SAP
764.1TF

Properties (6)

additional_info
SC398544
custom_field_two
3
customer
LACSD
datetime
2020-01-27T22:17:13-08:00
documentation
PRO PIPE
is_lateral_inspection
false