Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 7, 2020, 09:23 AM
  • A 0630_A 0629 _01072020_014527.mp4

Date
01/07/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07835
Time
1:23 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7233
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
33
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
A 0630
Downstream MH
A 0629
Dir. of Survey
Downstream
Length Surveyed
984.5 ft.
Total Length
984.5 ft.
Structural Index
3
Structural Quick
3f2f
Structural Rating
980
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
980
Pipe schematic from manhole A 0630 to A 0629
MH: A 0630MH: A 0629downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 06300 ft. MWM - Water Mark, 25 %of cross sectional area3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start3.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start981 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish984.5 ft. AMH - Downstream Manhole, Survey Ends - A 0629984.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
984.5AMHA 0629
0MWL
0AMHA 0630
0MWM
3SSS
984.5SAP
3.2SAP
981SSS

Properties (6)

additional_info
SC398526
custom_field_two
3
customer
LACSD
datetime
2020-01-07T01:23:04-08:00
documentation
PRO PIPE
is_lateral_inspection
false