Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 9, 2020, 09:17 AM
  • A 0623_A 0622 _01092020_012838.mp4

Date
01/09/2020
W/O
803106
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07828
Time
1:17 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7235
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
33
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
A 0623
Downstream MH
A 0622
Dir. of Survey
Downstream
Length Surveyed
522.3 ft.
Total Length
522.3 ft.
Structural Index
3
Structural Quick
3T2T
Structural Rating
518
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
518
Pipe schematic from manhole A 0623 to A 0622
MH: A 0623MH: A 0622downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 06230 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start4.6 ft. MGO - General Observation - MAG COAT4.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start463.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"520 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish522.3 ft. AMH - Downstream Manhole, Survey Ends - A 0622522.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
522.3AMHA 0622
520SSS
4.6MGOMAG COAT
522.3SAV
4.6SAV
0AMHA 0623
463.2TF
0MWL
3SSS
0MWM

Properties (6)

additional_info
SC398529
custom_field_two
3
customer
LACSD
datetime
2020-01-09T01:17:17-08:00
documentation
PRO PIPE
is_lateral_inspection
false