Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2020, 06:44 PM
  • A 0621_A 0620 _01282020_112837.mp4

Date
01/28/2020
W/O
803106
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00316
PipeID
P07826
Time
10:44 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7307
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
33
Purpose
Routine Assessment
Project
WO_803106_TV21027_DEC2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
A 0621
Downstream MH
A 0620
Dir. of Survey
Downstream
Length Surveyed
984.7 ft.
Total Length
984.7 ft.
Structural Index
3
Structural Quick
3f2f
Structural Rating
980
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
980
Pipe schematic from manhole A 0621 to A 0620
MH: A 0621MH: A 0620downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 06212 ft. MGO - General Observation - MAG COAT THROUGHOUT3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start3 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PARTIALLY VISIBLE979 ft. MGO - General Observation - MAG COAT THROUGHOUT END981 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish981 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish984.7 ft. AMH - Downstream Manhole, Survey Ends - A 0620

Observations (10)

DistanceCodeObservation
3SSS
0MWM
0MWL
979MGOMAG COAT THROUGHOUT END
984.7AMHA 0620
0AMHA 0621
981SSS
2MGOMAG COAT THROUGHOUT
981SAV
3SAVPARTIALLY VISIBLE

Properties (6)

additional_info
SC378784
custom_field_two
3
customer
LACSD
datetime
2020-01-28T10:44:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false